Compare commits

...

1 Commits

Author SHA1 Message Date
Andres
c10d33c6d8 MSA-1793: Hi,
We update the zwave version with our fingerprint data and we add the tamper alert.
Regards,
Andres V.
2017-02-17 21:41:56 -08:00

View File

@@ -0,0 +1,256 @@
/**
* Besense z-wave Door/window sensor
*/
metadata {
definition (name: "BeSense Door/Window Sensor", namespace: "BeSense", author: "BeSense") {
capability "Contact Sensor"
capability "Sensor"
capability "Battery"
capability "Configuration"
fingerprint mfr: "0214", prod: "0002", model: "0001", deviceJoinName: "BeSense Door/window sensor"
}
// simulator metadata
simulator {
// status messages
status "open": "command: 2001, payload: FF"
status "closed": "command: 2001, payload: 00"
status "wake up": "command: 8407, payload: "
}
// UI tile definitions
tiles(scale: 1) {
standardTile("contact", "device.contact", width: 3, height: 3, canChangeIcon: true) {
state ("open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#ea0f46")
state ("closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#27CC73")
}
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat") {
state "battery", label:'${currentValue}% battery', unit:""
}
main "contact"
details(["contact", "battery"])
}
}
def parse(String description) {
def result = null
if (description.startsWith("Err 106")) {
if (state.sec) {
log.debug description
} else {
result = createEvent(
descriptionText: "This sensor failed to complete the network security key exchange. If you are unable to control it via SmartThings, you must remove it from your network and add it again.",
eventType: "ALERT",
name: "secureInclusion",
value: "failed",
isStateChange: true,
)
}
} else if (description != "updated") {
def cmd = zwave.parse(description, [0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
if (cmd) {
result = zwaveEvent(cmd)
}
}
log.debug "parsed '$description' to $result"
return result
}
def updated() {
def cmds = []
if (!state.MSR) {
cmds = [
command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()),
"delay 1200",
zwave.wakeUpV1.wakeUpNoMoreInformation().format()
]
} else if (!state.lastbat) {
cmds = []
} else {
cmds = [zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}
response(cmds)
}
def configure() {
commands([
zwave.manufacturerSpecificV2.manufacturerSpecificGet(),
zwave.batteryV1.batteryGet()
], 6000)
}
def sensorValueEvent(value) {
if (value) {
createEvent(name: "contact", value: "open", descriptionText: "$device.displayName is open")
} else {
createEvent(name: "contact", value: "closed", descriptionText: "$device.displayName is closed")
}
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd)
{
sensorValueEvent(cmd.sensorValue)
}
def zwaveEvent(physicalgraph.zwave.commands.sensoralarmv1.SensorAlarmReport cmd)
{
sensorValueEvent(cmd.sensorState)
}
def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd)
{
def result = []
if (cmd.notificationType == 0x06 && cmd.event == 0x16) {
result << sensorValueEvent(1)
} else if (cmd.notificationType == 0x06 && cmd.event == 0x17) {
result << sensorValueEvent(0)
} else if (cmd.notificationType == 0x07) {
if (cmd.v1AlarmType == 0x07) { // special case for nonstandard messages from Monoprice door/window sensors
result << sensorValueEvent(cmd.v1AlarmLevel)
} else if (cmd.event == 0x01 || cmd.event == 0x02) {
result << sensorValueEvent(1)
} else if (cmd.event == 0x03) {
result << createEvent(descriptionText: "$device.displayName covering was removed", isStateChange: true)
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
} else if (cmd.event == 0x05 || cmd.event == 0x06) {
result << createEvent(descriptionText: "$device.displayName detected glass breakage", isStateChange: true)
} else if (cmd.event == 0x07) {
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
result << createEvent(name: "motion", value: "active", descriptionText:"$device.displayName detected motion")
}
} else if (cmd.notificationType) {
def text = "Notification $cmd.notificationType: event ${([cmd.event] + cmd.eventParameter).join(", ")}"
result << createEvent(name: "notification$cmd.notificationType", value: "$cmd.event", descriptionText: text, displayed: false)
} else {
def value = cmd.v1AlarmLevel == 255 ? "active" : cmd.v1AlarmLevel ?: "inactive"
result << createEvent(name: "alarm $cmd.v1AlarmType", value: value, displayed: false)
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
{
def event = createEvent(descriptionText: "${device.displayName} woke up", isStateChange: false)
def cmds = []
if (!state.MSR) {
cmds << command(zwave.manufacturerSpecificV2.manufacturerSpecificGet())
cmds << "delay 1200"
}
if (!state.lastbat || now() - state.lastbat > 53*60*60*1000) {
cmds << command(zwave.batteryV1.batteryGet())
} else {
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
}
[event, response(cmds)]
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
map.value = 1
map.descriptionText = "${device.displayName} has a low battery"
map.isStateChange = true
} else {
map.value = cmd.batteryLevel
}
state.lastbat = now()
[createEvent(map), response(zwave.wakeUpV1.wakeUpNoMoreInformation())]
}
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
def result = []
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
log.debug "msr: $msr"
updateDataValue("MSR", msr)
retypeBasedOnMSR()
result << createEvent(descriptionText: "$device.displayName MSR: $msr", isStateChange: false)
if (msr == "011A-0601-0901") { // Enerwave motion doesn't always get the associationSet that the hub sends on join
result << response(zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:zwaveHubNodeId))
} else if (!device.currentState("battery")) {
if (msr == "0086-0102-0059") {
result << response(zwave.securityV1.securityMessageEncapsulation().encapsulate(zwave.batteryV1.batteryGet()).format())
} else {
result << response(command(zwave.batteryV1.batteryGet()))
}
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
// log.debug "encapsulated: $encapsulatedCommand"
if (encapsulatedCommand) {
state.sec = 1
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
createEvent(descriptionText: "$device.displayName: $cmd", displayed: false)
}
private command(physicalgraph.zwave.Command cmd) {
if (state.sec == 1) {
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
} else {
cmd.format()
}
}
private commands(commands, delay=200) {
delayBetween(commands.collect{ command(it) }, delay)
}
def retypeBasedOnMSR() {
switch (state.MSR) {
case "0086-0002-002D":
log.debug "Changing device type to Z-Wave Water Sensor"
setDeviceType("Z-Wave Water Sensor")
break
case "011F-0001-0001": // Schlage motion
case "014A-0001-0001": // Ecolink motion
case "014A-0004-0001": // Ecolink motion +
case "0060-0001-0002": // Everspring SP814
case "0060-0001-0003": // Everspring HSP02
case "011A-0601-0901": // Enerwave ZWN-BPC
case "0214-0002-0002": // Besense pir or ceiling sensor
log.debug "Changing device type to Z-Wave Motion Sensor"
setDeviceType("Z-Wave Motion Sensor")
break
case "013C-0002-000D": // Philio multi +
log.debug "Changing device type to 3-in-1 Multisensor Plus (SG)"
setDeviceType("3-in-1 Multisensor Plus (SG)")
break
case "0109-2001-0106": // Vision door/window
log.debug "Changing device type to Z-Wave Plus Door/Window Sensor"
setDeviceType("Z-Wave Plus Door/Window Sensor")
break
case "0109-2002-0205": // Vision Motion
log.debug "Changing device type to Z-Wave Plus Motion/Temp Sensor"
setDeviceType("Z-Wave Plus Motion/Temp Sensor")
break
}
}